800-476-1486
International: 336-227-1486
Available 24 Hours, 7 Days
services contact us Live Chatlive chat

Need help with circuit breakers?

Call our breaker experts at 800-476-1486 or Chat Live

Cutler-Hammer
HMCP

Southland stocks a
full line of HMCP motor circuit protectors.

More Renewal Parts

Overload Relays Auxiliaries

NEED HELP FINDING THE RIGHT RENEWAL PART?

Call our experts at 800-476-1486 or Chat Live

Contact Kits


DISCONNECT TYPES

Fused
Non-fused

NEED HELP FINDING THE RIGHT DISCONNECT?

Call our disconnect experts at 800-476-1486 or Chat Live

Disconnects



Need help finding the right part?

Call our control experts at 800-476-1486 or Chat Live

Motor Starters

Southland stocks a full line of
Motor Starts, Contactors
and Renewal Parts


NEED HELP FINDING THE RIGHT
MOTOR CONTROL CENTER?

Call our MCC experts
800-476-1486 or Chat Live

Motor Control Centers

DRIVES/VFDS

LOGIC CONTROLS

SOFT STARTS

AUTOMATION SERVICES


NEED HELP WITH PLC OR AUTOMATION?

Call our automation experts at 866-736-1286 or Chat Live

Soft Starts

Southland stocks a full
line of parts for
all of your PLC
needs.


NEED HELP FINDING THE BUS PLUG?

Call our contactor experts at 800-476-1486 or Chat Live

Bus Plugs and Tap Boxes

Southland stocks a full
line of bus plugs
and tap boxes.


NEED HELP FINDING THE RIGHT TRANFORMER?

Call our transformer experts at 800-476-1486 or Chat Live

Transformers
Buy or Rent


Southland stocks a full
line of transformers
for sale or rent.
we have
short & long term
rental options

PCF362500DC1680 Square D Insulated Case Breaker
*Not a licensed Square D Distributor.

Square D   PCF362500DC1680

Download Cut Sheet
Description: 2500A 500Vdc 3P Std LS CB
Manufacturer: Square D
OEM Part Number: PCF362500DC1680
Our Part Number: PCF362500DC1680
Category: 2500 Amp 5 stars, based on 89 reviews
Product Questions? Call or Chat Live with a Electrical Specialist!

Order Online or Call 800-476-1486 to Order!

Hear what our customers have to say!


Ask a Question


 

Recent Product Questions

Alternative Part Number: PCF3625OODC168O, PCF3625OODC1680, PCF3625O0DC168O, PCF3625O0DC1680, PCF36250ODC168O, PCF36250ODC1680, PCF362500DC168O
DESCRIPTION
    SQD Square D Scheider Electric PCF362500DC1680 Standard Function LS Circuit Breaker
    • 2500 Amp
    • 500Vdc
    • 3 Pole
    • 125kA@240V, 100kA@480V, 65kA@600V(Std Func Therm-Mag Trip)
    • Standard Func LS Trip
    • Terminal Pads Only
    • 600-2500 Amp P Frame

    P
    FRAME
    C
    INTERRUPT RATING
    F
    TERMINATION
    3
    POLE
    6
    VOLT
    2500
    AMP
    -
    TRIP UNIT
    DC1680
    OPTIONS

    FRAME
    INTERRUPT RATING
    TERMINATION
    POLE
    VOLT
    AMP
    TRIP UNIT
    OPTIONS
    P=2500A
    A=65kA@240V, 50kA@480V, 42kA@600V(Std Func Therm-Mag)
    L=Line/Load Lugs
    2=2P
    2=240V
    000=Std MCS
    F=Frame Only
    DC=500Vdc
    H=125kA@240V, 100kA@480V, 65kA@600V(Std Func Therm-Mag)
    F=Terminal Pads
    3=3P
    4=480V
    600=600A
    BLANK=Std Func LS Trip
    MO1=120Vac Elec Oper
    C=125kA@240V, 100kA@480V, 65kA@600V(Std Func Therm-Mag)
    P=Lugs Load Side
    6=600V
    700=700A
    G=Std Func LSG Trip
    1042=24V 50/60Hz Shunt
    X=125kA@240V, 100kA@480V, 65kA@600V(Limit Func Elec)
    800=800A
    LI=Full Func LI Trip
    1048=48V 50/60Hz Shunt
    E=125kA@240V, 100kA@480V, 65kA@600V(Full Func Elec)
    900=900A
    LS=Full Func LS Trip
    1021=120V 50/60Hz Shunt
    1000=1000A
    LIG=Full Func LIG Trip
    1086=208-240V 50/60Hz Shunt
    1200=1200A
    LSG=Full Func LSG Trip
    1037=277-480V 50/60Hz Shunt
    1400=1400A
    LIA=Full Func LIA Trip
    1026=600V 50/60Hz Shunt
    1600=1600A
    LSA=Full Func LSA Trip
    1040=6Vdc Shunt
    2000=2000A
    M=Automatic MCS
    1039=12Vdc Shunt
    2500=2500A
    34M=1500-6500A MCP
    1027=24Vdc Shunt
    43M=3000-8000A MCP
    1028=48Vdc Shunt
    48M=6000-10000A MCP
    1038=72Vdc Shunt
    1029=125Vdc Shunt
    1030=250Vdc Shunt
    1143=24V 50/60Hz Undervoltage
    1157=48V 50/60Hz Undervoltage
    1121=120V 50/60Hz Undervoltage
    1122=208V 50/60Hz Undervoltage
    1124=240V 50/60Hz Undervoltage
    1142=227V 50/60Hz Undervoltage
    1148=380V 50/60Hz Undervoltage
    1149=415V 50/60Hz Undervoltage
    1134=440V 50/60Hz Undervoltage
    1125=480V 50/60Hz Undervoltage
    1126=600V 50/60Hz Undervoltage
    1136=6Vdc Undervoltage
    1133=12Vdc Undervoltage
    1127=24Vdc Undervoltage
    1128=48Vdc Undervoltage
    1135=72Vdc Undervoltage
    1129=125Vdc Undervoltage
    1130=250Vdc Undervoltage
    1212=1A1B Auxiliary Switch
    1352=2A2B Auxiliary Switch
    1364=3A3B Auxiliary Switch
    2100=N.O. Alarm Switch
    2103=N.C. Alarm Switch


    The Southland Advantages:

    • Exact match for many brands
    • We use OEM catalogs to match your part number
    • Competitively priced
    • Orders usually ship the same day
    • Individually inspected
    • Guaranteed for one full year

    Southland Electrical Supply has been in business for nearly 30 years, building a reputation for quality products at a reasonable price. Our inventory is far more extensive than what can be represented on our web site, so please call one of our knowledgeable salesmen with your specific needs.

    More information on circuit breakers




here: 0 0 0 0