Manufacturer:
Furnas
OEM Part Number:
Class 15
Category:
Furnas
Condition:
Manufacturer List Price:
Class 15
- NEMA Sizes 00-7 Open Enclosed NEMA-1, 3R, 12, 4X
- AC Contactors
- Magnetic Full Voltage Motor Starters
- Magnetic Full Voltage Reversing Motor Starters
- AC Automatic Transfer Switches
- Part Winding Starters
- Wye-Delta Starters
- Reduced Voltage Starters
- Multi Speed Starters
- Combination Starters
- Combination Multi Speed Starters
Three phase full voltage magnetic motor starters FVNR (full voltage non
reversing), FVR (full voltage reversing) & MSS (multi speed starter) connect
motors directly across the line allowing it to draw inrush current during
startup. Magnetic motor starters are most commonly used to control single
and three phase motors. The starters have a magnetically initiated contactor
(controlled by a coil) to make and break the power circuit and a thermal
overload relay for over current protection. Conventional thermal overloads
utilize heaters, or thermal overload heater strips, and are sized according
to the FLA (full load amperage). Solid state overloads have an adjustable
dial with a preset amp range.
For faster service please be prepared to furnish the following information:
- Application (saw mill edger, trash pump, elevator, trash compactor,
conveyor)
- Single or three phase
- Open or enclosed
- Enclosure type NEMA-1 (indoor) NEMA 3-R (outdoor) NEMA-12 (dust tight)
NEMA-4X (corrosion resistant)
- Line voltage 208/230/277/380/480/600 Volt
- Control or coil voltage 120/208/230/277/380/480/600 Volt
- Auxiliary contact arrangement (N.O. normally open) (N.C. normally closed)
- Controls (start stop buttons or pilot lights)
Southland Electrical Supply stocks new, new surplus, rebuilt and magnetic AC
motor starters, definite purpose and lighting contactors. Our magnetic AC
motor starters are professionally reconditioned (completely inspected,
disassembled, cleaned, reassembled, lubricated and electrically/mechanically
tested) and guaranteed for 1 full year.
We build and rebuild fractional and larger motor starters up to 400
horsepower**. Starters can be ordered open or enclosed for single and three
phase applications. We stock original and aftermarket renewal parts like
replacement contact kits, auxiliary contacts, replacement coils, armatures
and overload relays.
MCC & Combination units with fused or circuit breaker type disconnects as
well as custom specification starters can be assembled in less than a week.
Control power transformers, pilot lights, selector switches, emergency stop
and start stop buttons are common options. We specialize in rebuilding NEMA
(National Electrical Manufacturers Association) as well as IEC
(International Electrotechnical Commission) equipment.
The motor starter is an integral part of our complete MCC motor control
center offering. A large part of our business deals with up-fitting,
upgrading and reconditioning unitized motor control centers and building
custom pump panels for AC motors. With 30 years of business experience in
the same location and over 200 years of combined product knowledge,
Southland can exceed your expectations and deliver consistent high quality
magnetic AC motor starters at a substantial discount in a very short period
of time. Please call one of our dedicated sales professionals to configure a
starter for your application.
** Southland is an authorized distributor or Motortronics solid state
reduced voltage motor starters and AC inverters. Power demand planning and
local codes may specify reduced voltage motor starting. If you are affected
by any special requirement, please request more information about reduced
voltage starting for larger Horse Power applications.
More information on circuit breakers
Class 15
- NEMA Sizes 00-7 Open Enclosed NEMA-1, 3R, 12, 4X
- AC Contactors
- Magnetic Full Voltage Motor Starters
- Magnetic Full Voltage Reversing Motor Starters
- AC Automatic Transfer Switches
- Part Winding Starters
- Wye-Delta Starters
- Reduced Voltage Starters
- Multi Speed Starters
- Combination Starters
- Combination Multi Speed Starters
Three phase full voltage magnetic motor starters FVNR (full voltage non
reversing), FVR (full voltage reversing) & MSS (multi speed starter) connect
motors directly across the line allowing it to draw inrush current during
startup. Magnetic motor starters are most commonly used to control single
and three phase motors. The starters have a magnetically initiated contactor
(controlled by a coil) to make and break the power circuit and a thermal
overload relay for over current protection. Conventional thermal overloads
utilize heaters, or thermal overload heater strips, and are sized according
to the FLA (full load amperage). Solid state overloads have an adjustable
dial with a preset amp range.
For faster service please be prepared to furnish the following information:
- Application (saw mill edger, trash pump, elevator, trash compactor,
conveyor)
- Single or three phase
- Open or enclosed
- Enclosure type NEMA-1 (indoor) NEMA 3-R (outdoor) NEMA-12 (dust tight)
NEMA-4X (corrosion resistant)
- Line voltage 208/230/277/380/480/600 Volt
- Control or coil voltage 120/208/230/277/380/480/600 Volt
- Auxiliary contact arrangement (N.O. normally open) (N.C. normally closed)
- Controls (start stop buttons or pilot lights)
Southland Electrical Supply stocks new, new surplus, rebuilt and magnetic AC
motor starters, definite purpose and lighting contactors. Our magnetic AC
motor starters are professionally reconditioned (completely inspected,
disassembled, cleaned, reassembled, lubricated and electrically/mechanically
tested) and guaranteed for 1 full year.
We build and rebuild fractional and larger motor starters up to 400
horsepower**. Starters can be ordered open or enclosed for single and three
phase applications. We stock original and aftermarket renewal parts like
replacement contact kits, auxiliary contacts, replacement coils, armatures
and overload relays.
MCC & Combination units with fused or circuit breaker type disconnects as
well as custom specification starters can be assembled in less than a week.
Control power transformers, pilot lights, selector switches, emergency stop
and start stop buttons are common options. We specialize in rebuilding NEMA
(National Electrical Manufacturers Association) as well as IEC
(International Electrotechnical Commission) equipment.
The motor starter is an integral part of our complete MCC motor control
center offering. A large part of our business deals with up-fitting,
upgrading and reconditioning unitized motor control centers and building
custom pump panels for AC motors. With 30 years of business experience in
the same location and over 200 years of combined product knowledge,
Southland can exceed your expectations and deliver consistent high quality
magnetic AC motor starters at a substantial discount in a very short period
of time. Please call one of our dedicated sales professionals to configure a
starter for your application.
** Southland is an authorized distributor or Motortronics solid state
reduced voltage motor starters and AC inverters. Power demand planning and
local codes may specify reduced voltage motor starting. If you are affected
by any special requirement, please request more information about reduced
voltage starting for larger Horse Power applications.